Schneider Electric APC · Precision Cooling

Schneider Uniflair Room Precision Cooling (CRAC / CRAH)

Precision air conditioning that holds server room temperature and humidity within a tight band all year round.

Schneider Electric APC Uniflair Orta/Büyük Oda 4 photos

Comfort air conditioners are designed for people: they run during certain hours, do not manage humidity properly and focus largely on removing latent heat, in other words moisture. The load in a server room is almost entirely sensible heat and runs around the clock. Uniflair precision units are built for exactly that profile, with high airflow, accurate temperature control and integrated humidification and dehumidification designed for continuous duty.

The range follows two main approaches depending on the building. Direct-expansion CRAC units work with an outdoor condenser, while CRAH units connect to the building chilled water loop. Units can be specified as downflow, discharging into a raised floor, or upflow for rooms without one. Compact small-room models, ceiling split units and rack-mounted versions round out a family that scales from a single server room to large data halls.

Featured Models & Products

Uniflair LE (Leonardo Evolution)Uniflair TDAV / TUAV (DX)Uniflair TDCV / TUCV (Chilled Water)Uniflair Small RoomUniflair Rack MountedUniflair Ceiling Split

Key Features

Accurate temperature and humidity control

Tight control reduces the risk of static and condensation, keeping servers within the operating conditions their manufacturers recommend.

EC fan technology

Electronically commutated fans match airflow to demand, cutting energy use considerably at partial load.

Free-cooling options

On suitable models, compressor use is reduced when outdoor temperatures are low, lowering annual running costs.

Redundancy and rotation

Multiple units can back each other up and rotate duty to balance running hours.

Use Cases

  • Corporate server and system rooms
  • Raised-floor data halls
  • Telecom exchanges and base station shelters
  • IT centers in hospitals and public buildings
  • Temperature control in UPS and battery rooms

How to Choose the Right Model

Precision cooling capacity is calculated from the sum of IT load, UPS losses, lighting and heat gains through the building envelope. If the building has a chiller, choose a chilled water CRAH; otherwise a DX CRAC. Rooms with a raised floor suit downflow units, while rooms without one are better served by upflow or row-based solutions. Once total capacity is known, add at least one extra unit for N+1 redundancy. In regions with hot summers, size the outdoor units for peak ambient temperatures.

Frequently Asked Questions

What is wrong with using a regular split AC in a server room?
Comfort units are not designed for continuous duty, a high sensible heat ratio or humidity control. The usual result is frequent failures, uneven temperatures and excessive dehumidification, which precision cooling is designed to avoid.
What is the difference between CRAC and CRAH?
A CRAC unit is a direct-expansion system with its own compressor working with an outdoor condenser. A CRAH unit has no compressor and cools the air using chilled water supplied by the building chiller plant.
How often do Uniflair units need maintenance?
Filters, humidifier cylinders, fans and the refrigerant circuit all need regular checks. At least two preventive maintenance visits per year are usually recommended, with more frequent filter changes in dusty environments.