Schneider Uniflair Chillers, Heat Rejection and Liquid Cooling CDUs
The cooling plant that moves heat out of the data center, plus liquid cooling infrastructure for high-density racks.
Precision air conditioners remove heat from the room, but that heat still has to leave the building. In medium and large data centers, chillers take on that job. The Uniflair chiller family includes air-cooled, water-cooled and free-cooling options. Free-cooling models chill the water directly with outdoor air whenever it is cool enough, instead of relying on compressors, which lowers annual energy consumption, while dry coolers complete the heat rejection side.
AI and high-performance computing servers have pushed per-rack loads to levels that air struggles to carry. This is where direct-to-chip liquid cooling comes in, with coolant distribution units (CDUs) at the heart of the system. A CDU separates the facility water loop from the secondary loop feeding the servers through a heat exchanger, and controls flow, pressure and temperature to deliver a clean, stable supply to the cold plates.
Featured Models & Products
Key Features
Energy savings with free cooling
When outdoor conditions allow, compressor load is reduced or switched off entirely, delivering clear savings in the cooler months.
Air- or water-cooled choice
Air-cooled models suit rooftop or yard installation, while water-cooled versions fit sites with cooling towers.
Loop separation with CDUs
Thanks to the heat exchanger, facility water never reaches the servers, and the quality and pressure of the secondary loop are controlled separately.
Redundant pumps and filtration
Pump redundancy and fine filtration in CDUs are designed to prevent cold plate clogging and single points of failure.
Use Cases
- Central cooling plants for medium and large data centers
- AI training and inference clusters
- HPC systems at universities and research centers
- Chilled water loops serving InRow RC and Uniflair CRAH units
- Modernising existing chiller plants
How to Choose the Right Model
Chiller selection is driven by total cooling load, redundancy level and site layout. Choose air- or water-cooled depending on available space and water supply; in climates with many cool hours, free cooling shortens the payback period. For liquid cooling, start with the server vendor requirements for inlet water temperature, flow rate and water quality, then size CDUs redundantly for the number of racks. A hybrid design where air and liquid cooling work side by side is usually the most realistic approach.
Frequently Asked Questions
Does a free-cooling chiller make sense in a warm climate?
What is a CDU and why is it needed?
Can I add liquid cooling to my existing data center?
Related Product Groups
InRow Precision Cooling (InRow RC / RD / DX)
Uniflair Room Precision Cooling (LE / AM / TDAV)
Containment & Airflow Management
Uniflair Condensers, Fluid Coolers & Piping
Galaxy VL / VS / VX
Easy UPS 3L / 3M / 3S
Let us pick the right model for your project
Contact our team for site survey, product selection, installation and after-sales support.
TR
EN
DE