Schneider Electric APC · Precision Cooling

Schneider Uniflair Chillers, Heat Rejection and Liquid Cooling CDUs

The cooling plant that moves heat out of the data center, plus liquid cooling infrastructure for high-density racks.

Schneider Electric APC Uniflair Hava Soğutmalı Chiller 5 photos

Precision air conditioners remove heat from the room, but that heat still has to leave the building. In medium and large data centers, chillers take on that job. The Uniflair chiller family includes air-cooled, water-cooled and free-cooling options. Free-cooling models chill the water directly with outdoor air whenever it is cool enough, instead of relying on compressors, which lowers annual energy consumption, while dry coolers complete the heat rejection side.

AI and high-performance computing servers have pushed per-rack loads to levels that air struggles to carry. This is where direct-to-chip liquid cooling comes in, with coolant distribution units (CDUs) at the heart of the system. A CDU separates the facility water loop from the secondary loop feeding the servers through a heat exchanger, and controls flow, pressure and temperature to deliver a clean, stable supply to the cold plates.

Featured Models & Products

Uniflair Air-Cooled ChillerUniflair Water-Cooled ChillerUniflair Free-Cooling ChillerUniflair Dry CoolerLiquid-to-Liquid CDUFloor Standing CDU

Key Features

Energy savings with free cooling

When outdoor conditions allow, compressor load is reduced or switched off entirely, delivering clear savings in the cooler months.

Air- or water-cooled choice

Air-cooled models suit rooftop or yard installation, while water-cooled versions fit sites with cooling towers.

Loop separation with CDUs

Thanks to the heat exchanger, facility water never reaches the servers, and the quality and pressure of the secondary loop are controlled separately.

Redundant pumps and filtration

Pump redundancy and fine filtration in CDUs are designed to prevent cold plate clogging and single points of failure.

Use Cases

  • Central cooling plants for medium and large data centers
  • AI training and inference clusters
  • HPC systems at universities and research centers
  • Chilled water loops serving InRow RC and Uniflair CRAH units
  • Modernising existing chiller plants

How to Choose the Right Model

Chiller selection is driven by total cooling load, redundancy level and site layout. Choose air- or water-cooled depending on available space and water supply; in climates with many cool hours, free cooling shortens the payback period. For liquid cooling, start with the server vendor requirements for inlet water temperature, flow rate and water quality, then size CDUs redundantly for the number of racks. A hybrid design where air and liquid cooling work side by side is usually the most realistic approach.

Frequently Asked Questions

Does a free-cooling chiller make sense in a warm climate?
Even where free-cooling hours are fewer, winter months and night-time can still deliver meaningful savings. An energy analysis based on local annual temperature data should guide the decision.
What is a CDU and why is it needed?
A CDU is a distribution unit sitting between the facility water loop and the secondary loop feeding server cold plates. By separating the loops it controls water quality, pressure and temperature, and limits leak risk.
Can I add liquid cooling to my existing data center?
In most cases, yes. Liquid cooling is usually deployed for selected high-density racks alongside existing air cooling. Chilled water availability, pipe routing and floor loading should be assessed beforehand.

Let us pick the right model for your project

Contact our team for site survey, product selection, installation and after-sales support.