Schneider Electric Galaxy VS / VL / VX Three-Phase UPS
Scalable, high-efficiency double-conversion protection for data centers and critical facility loads.
Galaxy is the three-phase online UPS line Schneider Electric designs for medium to very large critical loads. Galaxy VS fits server rooms and smaller data halls thanks to its compact footprint, Galaxy VL brings a modular architecture to mid-sized data centers, and Galaxy VX and VXL serve facilities running in the megawatt range. Every model uses double-conversion topology, so the load stays fully isolated from disturbances on the utility side.
At this power level, choosing a UPS affects far more than outage behaviour: it also drives the electricity bill for the next decade. High-efficiency operating modes cut waste heat and therefore cooling demand, while parallel capability and modular power blocks let you add capacity in steps instead of oversizing on day one. Wherever downtime carries a direct price tag, from hospitals and banks to colocation providers and manufacturing plants, Galaxy sits at the heart of the power chain.
Featured Models & Products
Key Features
eConversion mode
Keeps the inverter engaged while cutting losses well below standard double conversion, which adds up to noticeable energy and cooling savings in larger facilities.
Hot-swappable power modules
On Galaxy VL and VX, power modules can be added or removed while the system is energised; the Live Swap design on Galaxy VL makes this safer for technicians.
Lithium-ion battery option
Longer service life, a smaller footprint and better tolerance of higher room temperatures than VRLA batteries, meaning fewer battery replacement cycles.
Parallel operation and N+1 redundancy
Several units can run in parallel for extra capacity or redundancy, so the load remains protected while one unit is being serviced.
Use Cases
- Colocation and enterprise data centers
- Hospital operating theatres, ICUs and imaging systems
- Core server rooms in banking and finance
- Process control and automation in manufacturing plants
- Public sector and university campus data halls
How to Choose the Right Model
Start by measuring the current IT load in kW and adding a realistic three-to-five-year growth plan. Below 150 kW, Galaxy VS usually does the job; between 200 and 500 kW, Galaxy VL lets you scale module by module; larger sites should look at VX or VXL. Next, define the runtime you need, how long your generator takes to pick up the load, and which battery chemistry suits the room. If you want N+1 redundancy, plan for one extra module or unit on top of the calculated capacity.
Frequently Asked Questions
What is the main difference between Galaxy VS and Galaxy VL?
Does eConversion mode put the load at risk?
Is lithium-ion worth it for a Galaxy UPS?
Related Product Groups
Easy UPS 3L / 3M / 3S
Smart-UPS (SMT / SMX / SRT / Ultra)
Back-UPS & Back-UPS Pro
Easy UPS On-Line (SRV) & BV Series
UPS Battery Cabinets, Replacement Batteries (RBC) & Bypass Panels
SurgeArrest & Power Conditioning
Let us pick the right model for your project
Contact our team for site survey, product selection, installation and after-sales support.