Schneider Electric Easy UPS 3S / 3M / 3L Three-Phase UPS
A straightforward, robust and service-friendly three-phase online UPS family for building-scale loads.
The Easy UPS three-phase family is aimed at facilities that need clean, uninterrupted power without data-center-grade complexity. The 3S covers small and medium loads, the 3M handles mid-sized buildings, and the 3L supports facility loads of several hundred kVA, while the modular version grows in power-block steps. Every model in the range runs true online double conversion.
What sets the range apart is how easy it is to install and maintain. Front access, a clear user interface and standard accessories shorten commissioning and make routine checks simpler for on-site teams. In buildings with mixed load profiles, such as lifts, lighting, ventilation and bedside equipment, it acts as a dependable buffer during generator transfers and grid fluctuations. For organisations looking for a three-phase solution that balances budget and performance, it is a sensible place to start.
Featured Models & Products
Key Features
Wide input tolerance
Fewer unnecessary transfers to battery on unstable mains or generator supply, which protects battery life and keeps the load steady.
Internal static and maintenance bypass
Keeps the load supplied during faults or planned service; on 3S models the maintenance bypass is built into the cabinet.
Parallel capability
Multiple units of the same model can run in parallel to add capacity or create a redundant system.
ECO mode and high efficiency
Where the load profile allows, ECO mode trims energy losses further, and online efficiency is already strong for this class.
Use Cases
- Production lines, PLC and SCADA panels in factories
- Critical building loads in hospitals and clinics
- Front desk, server room and security systems in hotels and resorts
- Central IT and checkout systems in malls and retail chains
- Floor server rooms and emergency loads in office buildings
How to Choose the Right Model
Model choice within Easy UPS 3 mostly follows the total building or facility load. Use the 3S below 40 kVA, the 3M between 60 and 200 kVA and the 3L for larger sites; if future growth is uncertain, the modular version keeps options open. Loads with high inrush current, such as motors and compressors, need extra headroom. Base battery runtime on your generator start-up time, and check switchboard and cable sizing during a site survey rather than from drawings alone.
Frequently Asked Questions
How do I choose between Easy UPS 3 and Galaxy?
Do Easy UPS three-phase models work well with generators?
Can I extend runtime with additional batteries?
Related Product Groups
Galaxy VL / VS / VX
Smart-UPS (SMT / SMX / SRT / Ultra)
Back-UPS & Back-UPS Pro
Easy UPS On-Line (SRV) & BV Series
UPS Battery Cabinets, Replacement Batteries (RBC) & Bypass Panels
SurgeArrest & Power Conditioning
Let us pick the right model for your project
Contact our team for site survey, product selection, installation and after-sales support.