Schneider Electric APC · Precision Cooling

Aisle Containment and Airflow Management

The first step to more cooling capacity is not losing the cold air you already produce.

Schneider Electric APC Pod Containment 4 photos

In many server rooms the cooling capacity looks sufficient on paper, yet hot spots still appear in the racks. The main reason is that cold supply air mixes with hot exhaust before it reaches the servers, or hot air recirculates to the front through empty rack spaces. The result is lower setpoints than necessary, cooling units working harder than they should and higher energy bills.

Containment prevents that mixing physically. Hot or cold aisle containment at pod level, air containment for single racks, blanking panels, brush-sealed cable entries and rack air distribution units together make airflow predictable. That frees up capacity from the cooling you already own and can postpone investment in additional cooling units.

Featured Models & Products

NetShelter Aisle ContainmentNetShelter Rack Air ContainmentRack Air Distribution Unit ACF002AR8136BLK Blanking PanelAirflow Management Kit

Key Features

Hot or cold aisle

The aisle between rack rows is closed with a roof and doors, separating hot and cold air zones.

Blanking panels

Panels that fill empty U spaces stop hot air from recirculating to the rack front and fit in seconds.

Rack-level option

Where aisle containment is not feasible, single-rack rooms can use rack-based containment and air ducting.

Air distribution units

Fan units mounted in the rack draw cold air from the raised floor towards the equipment intakes and reduce hot spots.

Use Cases

  • Raised-floor data halls
  • Server rooms with hot spots
  • Sites at the limit of cooling capacity
  • Colocation and rented rack space
  • Energy efficiency projects

How to Choose the Right Model

Start with measurements: logging rack inlet temperatures at the top, middle and bottom shows where the problem really is. In most rooms, blanking panels and sealed cable cut-outs deliver the first and quickest win. Where the row layout allows, aisle containment makes sense; small rooms with irregular layouts are better served by rack-based solutions. After containment, always have fire detection and suppression checked for the new airflow pattern.

Frequently Asked Questions

Hot aisle or cold aisle containment?
Both stop air mixing; the choice depends on the room layout, the cooling type and whether there is a raised floor. Hot aisle containment combined with InRow cooling is a common pairing.
Do blanking panels really make a difference?
Yes. Hot air recirculating through empty rack spaces causes servers to draw in warmer air; closing those gaps noticeably evens out inlet temperatures.
Can containment be retrofitted in an existing room?
If rack dimensions, row layout and ceiling height allow, installation is often possible while the room stays in operation. A site survey determines which containment type is feasible.

Let us pick the right model for your project

Contact our team for site survey, product selection, installation and after-sales support.