Schneider Electric APC · Precision Cooling

Uniflair Condensers, Fluid Coolers and Piping

An indoor precision cooling unit is only as good as the heat rejection equipment outside.

Schneider Electric APC Uniflair Kondenser 3 photos

InRow and room precision cooling units in server rooms and data centers have to release the heat they remove from IT equipment somewhere. That job falls to the outdoor equipment: air-cooled condensers for direct expansion (DX) systems, and fluid coolers (dry coolers) for water or glycol circuits. If these are poorly selected, capacity drops in summer and alarms start, however good the indoor unit is.

Under the Uniflair brand, Schneider Electric offers condensers and fluid coolers designed to work with its row and room units, along with piping distribution and connection accessories. Given the long, hot Aegean summers, sizing outdoor units for peak ambient temperature and placing them where airflow is unobstructed matters a great deal in our region.

Featured Models & Products

Uniflair Air Cooled CondensersUniflair Fluid CoolersUniflair InRow DXUniflair Room CoolingUniflair Piping Accessories

Key Features

Air-cooled condenser

Rejects the heat carried by the refrigerant of DX precision cooling units to outdoor air using fans.

Water/glycol fluid cooler

Cools a closed water or glycol loop with outdoor air and can support free cooling where the climate allows.

Matched system design

Selecting outdoor units together with Uniflair indoor units makes capacity and control matching easier.

Piping accessories

Distribution and connection parts help build a tidy, serviceable circuit between indoor and outdoor units.

Use Cases

  • Data center precision cooling
  • Server rooms with InRow DX cooling
  • Chilled water row and room units
  • Telecom exchanges
  • Replacing ageing outdoor units

How to Choose the Right Model

Base the design ambient temperature on the hottest days in your region; around Izmir and the inner Aegean, high summer temperatures persist for long periods. Pipe length and height difference between indoor and outdoor units affect capacity and oil return, so always check the manufacturer limits. On rooftops, watch for hot air recirculation, and near residential areas take fan noise into account.

Frequently Asked Questions

What is the difference between a condenser and a fluid cooler?
A condenser condenses refrigerant directly with outdoor air in DX systems. A fluid cooler cools a water or glycol mixture and works with chilled water indoor units or chiller systems.
How far can the outdoor unit be from the indoor unit?
Permitted pipe length and height difference are set by the manufacturer according to the indoor unit model and refrigerant type. Long runs may need extra measures for pipe sizing and oil return.
Can existing outdoor units be replaced?
Yes, an old condenser or fluid cooler can be replaced while keeping the indoor unit, but compatibility and capacity must be recalculated first.

Let us pick the right model for your project

Contact our team for site survey, product selection, installation and after-sales support.