Modular Power Distribution and Static Transfer Switches (STS)
For a flexible, redundant power path from the UPS all the way to the rack.
However reliable the UPS, a poorly designed path from there to the rack means one panel, cable or breaker can take down an entire row. The traditional approach runs a dedicated circuit from the panel for every new rack, which over time produces an infrastructure that is complex, hard to document and resistant to change.
Modular power distribution eases this with plug-in modules that attach to a distribution backbone running above or near the racks; when a new rack arrives, you simply add the matching module. A static transfer switch (STS) switches between two independent sources fast enough that the load does not notice, giving even single-corded equipment a redundant supply. At rack level, APC Rack ATS units do a similar job on a smaller scale.
Featured Models & Products
Key Features
Plug-in distribution modules
New racks are powered by adding a module to the backbone instead of pulling a long circuit from the panel.
Fast source transfer
When the STS detects a problem on the preferred source, it transfers the load electronically to the alternate one.
Redundancy for single-corded gear
Network and security devices with a single power supply can also benefit from A and B feeds.
Monitoring and metering
Distribution and transfer units can pass current and status data to monitoring systems.
Use Cases
- Medium and large data halls
- Critical rooms with A/B feeds
- Colocation facilities
- Single-corded network and security devices
- Halls with frequent layout changes
How to Choose the Right Model
For modular distribution, first estimate the final rack count and the expected power per rack, and size the backbone for that growth target. When sizing an STS, look beyond total load to whether the two sources are synchronised and what the short-circuit levels are. For single-rack needs, a Rack ATS is often sufficient and more practical. Have the selective coordination study done together with the electrical design.
Frequently Asked Questions
What is the difference between an STS and a Rack ATS?
Do dual-corded servers need an STS?
Can modular distribution be added to an existing hall?
Related Product Groups
NetShelter SX / CX / WX Racks
LCD Console & KVM Switch
Rack PDU (Basic / Metered / Switched / Metered-by-Outlet)
Prefabricated & Micro Data Center
Easy Rack, GO Rack & Easy Rack PDU
NetShelter Open Frame, Open Architecture & Specialty Enclosures
Let us pick the right model for your project
Contact our team for site survey, product selection, installation and after-sales support.
TR
EN
DE