APC Rack PDU Basic / Metered / Switched and Rack ATS

Power units that distribute, measure and remotely control the energy feeding every device in the rack.

Schneider Electric APC Rack PDU Metered 5 photos

The rack PDU is the last link between UPS and server, and often the component that receives the least attention. An ordinary power strip will not warn you of an overloaded rack, cannot show which device draws how much, and offers no way to reboot a frozen device remotely. The APC Rack PDU family is tiered around these needs: Basic models provide reliable distribution, Metered models display total current, Metered-by-Outlet models measure every socket, and Switched models turn individual outlets on and off remotely.

In high-density racks, knowing phase balance and breaker limits is the only way to avoid an unexpected trip. Network-connected PDUs pass this data to a web interface, SNMP and monitoring software, raising alarms when thresholds are crossed. For single-corded devices, a Rack ATS automatically selects one of two feeds, extending the benefits of a redundant power design to equipment with only one power supply.

Featured Models & Products

AP7553AP7920BAP8853AP8858AP8959EU3AP4421AAP4423ANetShelter Advanced Rack PDU

Key Features

Tiered metering and control

Choose between pure distribution, total current metering, per-outlet metering or remote outlet switching as your needs require.

Sequenced start-up and remote reboot

Switched models power outlets on in sequence when power returns to avoid inrush, and frozen devices can be restarted without a site visit.

Zero U and horizontal mounting

Vertical Zero U models mount at the back of the rack without using rack units, while 1U horizontal models suit smaller cabinets.

Dual feed with Rack ATS

Single-corded devices such as switches and firewalls are fed from two sources, transferring automatically if one fails.

Use Cases

  • Server racks in data centers and server rooms
  • Per-customer energy metering in colocation
  • Remote reboot of devices at branch sites
  • Redundant power for single-corded network devices
  • Rack-level capacity planning and energy reporting

How to Choose the Right Model

Start with the input supply: single-phase 16 A, single-phase 32 A or three-phase determines the PDU model directly. Then count the outlet types your equipment needs; servers typically use C13, while high-power devices need C19. Total load should stay below 80 percent of circuit capacity. If you do not need remote access, Basic is enough; choose Metered for capacity tracking and Switched for remote reboots at unmanned sites. For dual-corded servers, plan two separate PDUs per rack.

Frequently Asked Questions

What is the difference between Metered and Switched PDUs?
A Metered PDU measures current draw and reports it over the network but does not control outlets. A Switched PDU adds the ability to turn each outlet on or off remotely and to define the power-up sequence.
When do I need a Rack ATS?
A Rack ATS is used to connect devices with only one power supply to two different feeds. If a UPS or circuit fails, those devices switch automatically to the other source.
Can I monitor temperature through the PDU?
Most network-connected APC Rack PDUs accept an optional temperature and humidity sensor. That lets you track the rack environment without installing a separate monitoring appliance.