APC Rack PDU Basic / Metered / Switched and Rack ATS
Power units that distribute, measure and remotely control the energy feeding every device in the rack.
The rack PDU is the last link between UPS and server, and often the component that receives the least attention. An ordinary power strip will not warn you of an overloaded rack, cannot show which device draws how much, and offers no way to reboot a frozen device remotely. The APC Rack PDU family is tiered around these needs: Basic models provide reliable distribution, Metered models display total current, Metered-by-Outlet models measure every socket, and Switched models turn individual outlets on and off remotely.
In high-density racks, knowing phase balance and breaker limits is the only way to avoid an unexpected trip. Network-connected PDUs pass this data to a web interface, SNMP and monitoring software, raising alarms when thresholds are crossed. For single-corded devices, a Rack ATS automatically selects one of two feeds, extending the benefits of a redundant power design to equipment with only one power supply.
Featured Models & Products
Key Features
Tiered metering and control
Choose between pure distribution, total current metering, per-outlet metering or remote outlet switching as your needs require.
Sequenced start-up and remote reboot
Switched models power outlets on in sequence when power returns to avoid inrush, and frozen devices can be restarted without a site visit.
Zero U and horizontal mounting
Vertical Zero U models mount at the back of the rack without using rack units, while 1U horizontal models suit smaller cabinets.
Dual feed with Rack ATS
Single-corded devices such as switches and firewalls are fed from two sources, transferring automatically if one fails.
Use Cases
- Server racks in data centers and server rooms
- Per-customer energy metering in colocation
- Remote reboot of devices at branch sites
- Redundant power for single-corded network devices
- Rack-level capacity planning and energy reporting
How to Choose the Right Model
Start with the input supply: single-phase 16 A, single-phase 32 A or three-phase determines the PDU model directly. Then count the outlet types your equipment needs; servers typically use C13, while high-power devices need C19. Total load should stay below 80 percent of circuit capacity. If you do not need remote access, Basic is enough; choose Metered for capacity tracking and Switched for remote reboots at unmanned sites. For dual-corded servers, plan two separate PDUs per rack.
Frequently Asked Questions
What is the difference between Metered and Switched PDUs?
When do I need a Rack ATS?
Can I monitor temperature through the PDU?
Related Product Groups
NetShelter SX / CX / WX Racks
LCD Console & KVM Switch
Prefabricated & Micro Data Center
Easy Rack, GO Rack & Easy Rack PDU
NetShelter Open Frame, Open Architecture & Specialty Enclosures
Rack Accessories
Let us pick the right model for your project
Contact our team for site survey, product selection, installation and after-sales support.
TR
EN
DE