Server Room Raised Floor and Infrastructure

Raised floor, precision cooling, power infrastructure, fire suppression and physical security for server and system rooms — designed in line with the TIA-942 standard.

Server Room Design and Raised Floor Installation in İzmir

A professional server room is the foundation for IT equipment that runs safely, efficiently and without interruption. Raised flooring, cable management, cooling and power distribution must be designed as a single, coherent system — not added piece by piece.

Teknolojik Bilgisayar designs and builds server rooms in line with the TIA-942 standard. Whether you want to upgrade an existing room or build a new one from scratch, we provide an end-to-end service for companies in İzmir and the Aegean region: from the raised floor and precision air conditioning to UPS, fire suppression, access control and environmental monitoring.

Server Room Components

  • Raised floor: Cable management and controlled airflow under the floor
  • Cooling: Precision air conditioning and hot/cold aisle separation
  • Power: UPS, PDU, generator and grounding
  • Security: Access control, CCTV and fire suppression

Benefits

  • Standards-based: Design aligned with TIA-942
  • Energy savings: Optimized airflow reduces cooling costs
  • Protection: Early fire warning, leak detection and physical access control
  • Proactive maintenance: Environmental monitoring and periodic maintenance contracts

Planning Guidance

Cooling capacity is calculated from the total heat output of your equipment in kW plus a 30% growth margin, with an additional unit for N+1 redundancy. A raised floor of at least 30 cm is recommended, and 45-60 cm is ideal for dense cabling and underfloor cooling. We work with APC/Schneider Electric, Rittal, Vertiv, Legrand and VESDA, and offer maintenance contracts covering UPS, cooling and fire systems.

Our Services

Raised Floor

Steel or aluminum raised floor systems, 30-60 cm high, with anti-static surface and perforated ventilation panels.

Precision Cooling

Precision AC systems, in-row cooling and hot/cold aisle separation, with temperature and humidity sensors monitored .

Power Infrastructure

Online UPS with N+1 redundancy, intelligent PDUs and automatic transfer switches (ATS), plus energy monitoring and capacity planning.

Fire Detection and Suppression

VESDA early warning and FM-200/Novec gas suppression, with smoke detectors and a fire alarm panel.

Physical Security

Biometric or card access control, CCTV and water leak sensors, with visitor registration and access logs.

Environmental Monitoring

DCIM software for temperature, humidity, power consumption and capacity monitoring, with alarms and reporting.

Our Process

01

Discovery & Analysis

Current infrastructure audit, needs assessment and capacity planning

02

Design

Topology design, equipment selection and technical specification

03

Implementation

Physical installation, configuration and integration

04

Testing & Go-Live

Comprehensive testing, performance measurement and documentation

05

Maintenance & Support

Proactive monitoring, regular maintenance and technical support

Frequently Asked Questions

Why is a raised floor necessary?
A raised floor simplifies cable management, optimizes cold air distribution and provides flexibility for future changes.
How high should the raised floor be?
We recommend at least 30 cm. In environments with dense cabling and underfloor cooling, 45-60 cm is ideal. The final height depends on the room height.
Can a raised floor be added to an existing room?
Yes, provided the ceiling height is sufficient (at least 2.7 m clear). Equipment is temporarily relocated while the floor is installed.